Page view 8
Connect
Hose and Gun
Remove the plastic plug from the pressure control
outlet nipple. Connect the main fluid hose to the fluid
outlet of the pressure control. See Fig 1. Connect the
shorter hose to the main hose and then connect a spray
gun to the other end of the hose. Don’t use thread
sealant, and don’t install the spray tip yet!
WARNING
If you are supplying your own hoses and spray
gun, be sure they are electrically grounded and
rated
for at
least m psi (210
b8r)
Working
Pressure and that the gun has a tip guard. This is
to reduce the risk of serious bodly injury caused by
static sparking, fluid injection or overpressurizing
and rupturing the equipment.
For two gun hookup, remove the plastic cap plug from
the l/4 npsm(f 1 nipple and connect an accessory hose
and spray gun. See Fig 1.
CAUTION
To avoid damaging the pressure control, which
may result in poor equipment performance and
component damage, follow these precautions:
1. Always use at least 50 ft (15 ml of nylon
spray hose.
2. Never use a wire braid hose as it is too rigid to
act as a pulsation dampener.
3. Never install any shutoff device between the
fluid outlet of the pressure control and the
first 50 ft (15 m) of spray hose.
4. Always use the main fluid outlet for one-gun
operation. Never plug this outlet.
Fill Packing Nut/Wet Cup
Pour throat seal liquid, supplied with the sprayer, into
the packing nut/wet-cup until it is l/3 full. Keep the
wet-cup filled to help protect and prolong the life of the
pump throat packings. See Fig 2.
Check Electrical Service
Be sure the electrical service is 126 V, 60 HzAc,
15 amp (minimum) and that the outlet you use is pro-
perly grounded.
Use an extension cord which has 3 wires of minimum 12
gauge size, rated for 15 Amps, and a maximum of
150 ft (45 m) long. Longer lengths may affect sprayer
performance.
Plug In Sprayer
Be sure the ON/OFF switch is OFF. Plug the power sup-
ply cord into a grounded elec:rical outlet that is at least
26 ft (6 m) away from the spray area to reduce the
chance of a spark igniting the spray vapors. See Fig 3.
Do not remove the third prong of the power supply cord
plug, which is the grounding prong, and do not use an
adapter.
Flush the Pump
Flush the pump to remove the lightweight oil which was
left in to protect pump parts after factory testing. Refer
to page 12 for WHEN and HOW to flush.
Fig 1
SECONDARY
Fig 2
Fig 3
Prepare the Paint
Prepare the paint according to the manufacturer’s
recommendations. Remove any skin that may have
formed, and stir the paint to dissolve hard pigments.
Strain the paint through a fine nylon mesh bag
(available at most paint dealers) to remove particles that
could clog the spray tip. This is probably the most im-
portant step toward trouble-free spray painting.
820447