TYPE OF PROBLEM
MOTOR WON’T OPERATE
WHAT TO CHECK
WHAT TO DO
If check is OK, to to next check
When check is not OK refer to thii column
Diagnosing circuit board in-
1. Check leads from bridge 13081 to motor to be 1. Replace any loose terminals and crimp to
dicator lamps. The normal
sure they are securely fastened and properly
leads. Be sure male terminal blades are
condition is red lamp on,
mated.
straight and firmly connected to mating part.
clear lamp on when
boerd is
telling pump to run.
2. Check Gl and G2 connections between cir-
2. Clean circuit board male terminals. Replace
cuit board (23) and bridge 008) for damage loose or damaged terminals. Securely recon-
Follow Pressure Relief Pro-
or loose terminals. nect leads.
cedure. Remove gun from
hose. Remove pressure con-
3. Check for loose motor brush lead connec- 3. Tighten terminal screws.
Rapl8Ce
brushes if
trol cover and check for faulty
tions and terminals. See page 22. leads are damaged. See page 22.
condition of circuit board
lamps. 4. Check brush length which should be l/2” 4. Replace brushes. See page 22.
minimum. See page 22.
Condition A both lamps on;
NOTE: Brushes do not wear at the same
pump won’t operate and
rate on both sides of motor.
motor is not running
5. Check for broken or misaligned motor brush 5. Replace spring if broken. Realign spring with
springs. Rolled portion of spring must rest brush. See page 22.
squarely on top of brush. See page 22.
6. Check motor brushes for binding in brush
holders. Sea page 22.
6. Clean brush holders. Remove carbon with
small cleaning brush. Align brush lead with
slot in brush holder to assure free vertical
brush movement.
7. Check motor armature commutator for burn 7. Remove motor and have motor shop resur-
spots, gouges and extreme roughness. face commutator if possible. See page 36.
Remove motor cover and brush inspection
plates to check. See page 22.
8. Check motor armature for shorts using ar- 8. Replace motor. See page 36.
mature tester (growler) or perform spin test.
See page 19
9. Check bridge (3!38) by substituting with a 9. Replace bridge. See page 24.
good bridge or performing bridge test. See
page 20.
CAUTION: Do not perform this check until
armature is determined to be good. A bad
armature will immediately burn out a good
bridge.
Condition B
Both lamps off
1. Check circuit breaker 069) button to be sure
1. Depress circuit breaker button to reset. If cir
it has not popped up. cuit breaker continues to open, see “Elec-
trical Short”, 18.
2. Check sprayer power supply cord (311).
2. Replace power supply cord. See page 23.
Disconnect TP6 female end TPl female and
connect volt meter to these leads. Plug in
sprayer. Meter should read 105 to 125 VAC.
Unplug sprayer. Reconnect TPl.
3. Check ON/OFF switch 003). Disconnect TP2 3. Replace ON/OFF switch. See page 23.
and connect volt meter to TP6 female and
TP2 male. Plug in sprayer and turn on. Meter
should read 105 to 125 VAC. Turn off and
unplug sprayer. Reconnect TP2.
4. Check jumper wire KIO6). Disconnect TP3
4. Replace jumper wire. See page 24.
and connect volt meter to TP6 female and
TP3 female. Plug in sprayer and turn on.
Meter should read 105 to 125 VAC. Turn off
and unplug sprayer. Reconnect TP3.
5. Check circuit breaker 009). Connect volt 5. Replace circuit breaker. See page 24.
meter to TP6 female and TP4. Plug in
sprayer and turn on. Meter should read 105
to 125 VAC. Turn off and unplug sprayer.
Troubleshooting continued on nextpege.